dc.contributor.author | Киселев, М. Г. | |
dc.contributor.author | Монич, С. Г. | |
dc.contributor.author | Петров, В. А. | |
dc.contributor.author | Ахмад Али | |
dc.contributor.author | Kiselev, M. G. | |
dc.contributor.author | Monich, S. G. | |
dc.contributor.author | Petrov, V. A. | |
dc.contributor.author | Ahmad Ali | |
dc.date.accessioned | 2020-06-25T07:27:34Z | |
dc.date.available | 2020-06-25T07:27:34Z | |
dc.date.issued | 2020 | |
dc.identifier.citation | Киселев, М. Г. Влияние продолжительности остановки шток-поршня шприца однократного применения перед стадией выдавливания жидкости на величину усилия, необходимого для его перемещения / М. Г. Киселёв, С. Г. Монич, В. А. Петров, Ахмад Али // Вестник Белорусско-Россйиского университета.- 2020.- № 2.- С. 97-105 | ru_RU |
dc.identifier.uri | http://e.biblio.bru.by/handle/1212121212/12881 | |
dc.description.abstract | Статья посвящена количественной оценке влияния продолжительности остановки шток-поршня шприца между стадиями всасывания жидкости и её последующего выдавливания на величину усилия, необходимого для его перемещения, а также в обосновании, на основе полученных экспериментальных данных, значения этого параметра при проведении испытания шприцев. Создано устройство, позволяющее регистрировать и измерять величину усилия, необходимого для движения шток-поршня медицинских шприцев однократного применения, а также разработана методика проведения экспериментов по оценке влияния продолжительности остановки шток-поршня между стадиями всасывания жидкости и её последующего выдавливания на значение этого усилия для двух- и трёхкомпонентного шприцев емкостью 3 мл. The article is devoted to a quantitative assessment of the influence of duration of stopping a syringe plunger rod between the stages of liquid suction and its subsequent extrusion on the amount of force required for its movement, as well as to an experimental data-based substantiation of the value of this parameter, when testing syringes. A device has been created that detects and measures the amount of force required to move a plunger rod of disposable syringes, and a testing procedure has been developed for conducting experiments to assess the impact of duration of stopping a plunger rod between the stages of liquid suction and subsequent extrusion on the value of this force for two- and three-component 3 ml syringes. | ru_RU |
dc.language.iso | ru | ru_RU |
dc.publisher | Белорусско-Российский университет | ru_RU |
dc.subject | инъекционный шприц | ru_RU |
dc.subject | шток-поршень | ru_RU |
dc.subject | усилие движения | ru_RU |
dc.subject | стадия выдавливания | ru_RU |
dc.subject | стадия всасывания | ru_RU |
dc.subject | устройство | ru_RU |
dc.subject | методика проведения испытаний | ru_RU |
dc.subject | injection syringe | ru_RU |
dc.subject | plunger rod | ru_RU |
dc.subject | travel force | ru_RU |
dc.subject | extrusion stage | ru_RU |
dc.subject | suction stage | ru_RU |
dc.subject | device | ru_RU |
dc.subject | testing procedure | ru_RU |
dc.title | Влияние продолжительности остановки шток-поршня шприца однократного применения перед стадией выдавливания жидкости на величину усилия, необходимого для его перемещения | ru_RU |
dc.title.alternative | Effect of duration of stopping a disposable syringe plunger rod before liquid extrusion stage on the amount of force required to move it | ru_RU |
dc.type | Article | ru_RU |
dc.identifier.udc | 615.473:620.174.21 |