Показать сокращенную информацию
dc.contributor.author | Далимаев, В. А. | |
dc.contributor.author | Подымако, М. Э. | |
dc.contributor.author | Коваленко, М. В, | |
dc.contributor.author | Dalimaev, V. A. | |
dc.contributor.author | Podymako, M. E. | |
dc.contributor.author | Kovalenko, M. V. | |
dc.date.accessioned | 2024-12-11T06:42:27Z | |
dc.date.available | 2024-12-11T06:42:27Z | |
dc.date.issued | 2024 | |
dc.identifier.citation | Далимаев, В. А. Расчетно-экспериментальный подход к оценке вентилирования кабины лифта пассажирского и поиск резервов для его улучшения / В. А. Далимаев, М. Э. Подымако, М. В. Коваленко // Вестник Белорусско-Российского университета. – 2024. – № 4 (85). – С. 5–16. DOI 10.24412/2077-8481-2024-4-5-16 | ru_RU |
dc.identifier.uri | http://e.biblio.bru.by/handle/1212121212/44032 | |
dc.description.abstract | Проведен анализ нормативных документов и сформированы критерии для оценки уровня качества вентилирования в кабине лифта. Прибором ТКА-ПКМ 52 измерены численные значения скорости воздуха внутри кабины при включенном вентиляторе на вдув и выдув. Также определено численное значение скорости воздуха в шахте лифта (тяга в шахте). Создана и подготовлена расчетная модель. Выделены граничные условия и проведены вычислительные эксперименты для проверки общепринятых подходов расчета аэродинамики применительно к кабине лифта. Проведен расчет методом конечных элементов. Опираясь на результаты эксперимента, проведена валидация расчетной модели. По результатам расчета сделаны выводы о применимости подходов, дана оценка уровню качества вентилирования в кабине лифта производства ОАО «Могилевлифтмаш». An analysis of regulatory documents was carried out and criteria were formed to assess the level of ventilation quality in the elevator cabin. The TKA-PKM 52 device measured numerical values of the airflow velocity inside the cabin with the ventilation fan switched for inlet/outlet. Also, the numerical value of the airflow velocity in the elevator shaft (thrust in the shaft) was determined. A calculation model was created and prepared. Boundary conditions were identified, and computational experiments were carried out to verify generally accepted approaches to calculating aerodynamics as applied to the elevator car. The calculation was carried out using the finite element method. Based on the experimental results, the calculation model was validated. On the basis of calculation results, conclusions were drawn about the applicability of the approaches, and the level of ventilation quality in the elevator cabin produced by OJSC Mogilevliftmash was assessed. | ru_RU |
dc.language.iso | ru | ru_RU |
dc.publisher | Белорусско-Российский университет | ru_RU |
dc.subject | комфорт | ru_RU |
dc.subject | лифт | ru_RU |
dc.subject | метод конечных элементов | ru_RU |
dc.subject | аэродинамика | ru_RU |
dc.subject | воздухообмен | ru_RU |
dc.subject | вентиляция | ru_RU |
dc.subject | comfort | ru_RU |
dc.subject | elevator | ru_RU |
dc.subject | finite element method | ru_RU |
dc.subject | aerodynamics | ru_RU |
dc.subject | air exchange | ru_RU |
dc.subject | ventilation | ru_RU |
dc.title | Расчетно-экспериментальный подход к оценке вентилирования кабины лифта пассажирского и поиск резервов для его улучшения | ru_RU |
dc.type | Article | ru_RU |