Исследование влияния температуры объекта на результаты ультразвукового контроля различными методами

Показать сокращенную информацию

dc.contributor.author Сергеев, С. С.
dc.contributor.author Воронов, Е. Д.
dc.contributor.author Толкачев, Р. А.
dc.contributor.author Sergeev, S. S.
dc.contributor.author Voronov, E. D.
dc.contributor.author Tolkachev, R. A.
dc.date.accessioned 2024-12-11T07:07:30Z
dc.date.available 2024-12-11T07:07:30Z
dc.date.issued 2024
dc.identifier.citation Сергеев, С. С. Исследование влияния температуры объекта на результаты ультразвукового контроля различными методами / С. С. Сергеев, Е. Д. Воронов, Р. А. Толкачев // Вестник Белорусско-Российского университета. – 2024. – № 4 (85). – С. 48–56. DOI 10.24412/2077-8481-2024-4-48-56 ru_RU
dc.identifier.uri http://e.biblio.bru.by/handle/1212121212/44036
dc.description.abstract Проведены экспериментальные исследования влияния температуры объекта контроля и преобразо- вателей на результаты ультразвукового контроля по двум технологиям: эхо-импульсный метод на фазиро- ванных решетках и TOFD-метод. Установлено, что при повышении температуры измерительного тракта для эхо-импульсного метода амплитуда сигнала от дефекта существенно увеличивается, что оказывает значительное влияние на измеряемые размеры дефекта. Кроме того, с увеличением температуры наблю- дается незначительное уменьшение измеренной глубины залегания отражателей (дефектов). Для TOFD-метода погрешности измерения размеров отражателей (дефектов) и глубины их залегания в диапа- зоне температур объекта 20 °C...60 °C не превышают 5 %, что допускается нормативными документами. Приведены практические рекомендации для снижения погрешностей измерения параметров дефектов при высокотемпературном контроле. Experimental studies have been carried out to determine how the temperature of a test object and transducers influences the results of ultrasonic testing in the two technologies used – the pulse-echo method on phased arrays and the TOFD method. It has been established that with an elevation of temperature of the measuring path for the pulse-echo method, the amplitude of a signal from a defect increases significantly, which has a significant impact on the measured dimensions of the defect. In addition, with a temperature increase, a slight decrease in the measured depth of reflectors (defects) is observed. For the TOFD method, errors in measuring the dimensions of reflectors (defects) and the depth of their occurrence do not exceed 5 % in the object temperature range of 20 °C...60 °C, which is allowed by the regulatory documents. Practical recommendations are given for reducing errors in measuring the defect parameters during high-temperature control. ru_RU
dc.language.iso ru ru_RU
dc.publisher Белорусско-Российский университет ru_RU
dc.subject ультразвуковой контроль ru_RU
dc.subject фазированные решетки ru_RU
dc.subject температура ru_RU
dc.subject сварное соединение ru_RU
dc.subject дефект ru_RU
dc.subject ultrasonic testing ru_RU
dc.subject phased arrays ru_RU
dc.subject temperature ru_RU
dc.subject welded joint ru_RU
dc.subject defect ru_RU
dc.title Исследование влияния температуры объекта на результаты ультразвукового контроля различными методами ru_RU
dc.title.alternative Investigation of the influence of object temperature on the results of ultrasonic testing by various methods ru_RU
dc.type Article ru_RU


Файлы в этом документе

Данный элемент включен в следующие коллекции

Показать сокращенную информацию