Интегративный показатель тревог как объективный критерий эффективной синхронизации ИВЛ

Показать сокращенную информацию

dc.contributor.author Дудко, В. А.
dc.contributor.author Дорошкова, Т. И.
dc.contributor.author Липницкий, А. Л.
dc.contributor.author Марочков, А. В.
dc.contributor.author Ливинская, В. А.
dc.contributor.author Dudko, V. A.
dc.contributor.author Doroshkova, T. I.
dc.contributor.author Lipnitski, A. L.
dc.contributor.author Marochkov, A. V.
dc.contributor.author Livinskaya, V. A.
dc.date.accessioned 2026-07-22T07:11:24Z
dc.date.available 2026-07-22T07:11:24Z
dc.date.issued 2025
dc.identifier.citation Интегративный показатель тревог как объективный критерий эффективной синхронизации ИВЛ / В. А. Дудко, Т. И. Дорошкова, А. Л. Липницкий [и др.] // Вестник Витебского государственного медицинского университета. – 2025. – Т. 24, № 2. – С. 63-70. ru_RU
dc.identifier.uri http://e.biblio.bru.by/handle/1212121212/48224
dc.description.abstract Цель исследования – проанализировать эпизоды взаимодействия аппаратного дыхания и спонтанного дыхания пациента на основании показателей тревожной сигнализации респиратора и разработать интегративный показатель тревог для количественной оценки степени десинхронизации. Материал и методы. В данной работе проанализированы 242 эпизода длительной ИВЛ у 44-х пациентов с ОРДС (острым респираторным дистресс-синдромом) различной этиологии и различной степени тяжести. Для количественной оценки степени десинхронизации нами был разработан интегративный показатель тревог (ИПТ), который представляет собой сумму эпизодов срабатывания тревожной сигнализации аппарата ИВЛ при превышении установленных пределов тревог следующих параметров: пиковое давление на вдохе (Ppеак), частота вентиляции (f), объем минутной вентиляции (MV) и дыхательный объем (Vt) за единицу времени – 1час. Результаты. Были получены достоверные отличия между группами ИПТ по следующим параметрам: минутный объем вентиляции (MV), дыхательный объем (Vt), частота (Fобщ), парциальное давление CO2 в выдыхаемой смеси (etCO2 ), объем образовавшегося CO2 (VCO2 ), податливость (Compl), триггер (Trigger). Группы ИТП достоверно отличались по глубине седации с применением фентанила, по уровню седации, определенному с помощью ЭЭГ-мониторинга и шкале Ramsay. Заключение. Интегративный показатель тревог является независимым от других показателей тревог критерием, характеризующим степень оптимального уровня соответствия дыхательных циклов аппарата ИВЛ и спонтанного дыхания больного. Objectives. To analyze the episodes of interaction between mechanical ventilation and spontaneous breathing of a patient based on the indicators of the respirator alarm signal and to develop an integrative alarm indicator for the quantitative assessment of the desynchronization degree. Material and methods. In this work, 242 episodes of prolonged mechanical ventilation were analyzed in 44 patients with ARDS (acute respiratory distress syndrome) of various etiologies and varying degrees of severity. To assess quantitatively 64 the desynchronization degree, we developed an integrative alarm indicator (IAI), which is the sum of the episodes of the ventilator alarm signal triggering when the set alarm limits of the following parameters are exceeded: peak inspiratory pressure (Ppеак), ventilation frequency (f), minute ventilation volume (MV) and tidal volume (Vt) per unit of time - 1 hour. Results. Significant differences were obtained between the IAI groups in the following parameters: minute ventilation volume (MV), tidal volume (Vt), frequency (Ftotal), partial pressure of CO2 in the exhaled mixture (etCO2 ), volume of formed CO2 (VCO2 ), Compliance (Compl), Trigger (Trigger). The IAI groups differed significantly in the depth of sedation using fentanyl, in the level of sedation determined by EEG monitoring and the Ramsay scale. Conclusions. The integrative anxiety index is a criterion independent of other anxiety indices, characterizing the degree of optimal compliance between the respiratory cycles of the ventilator and the patient’s spontaneous breathing ru_RU
dc.language.iso ru ru_RU
dc.subject искусственная вентиляция легких ru_RU
dc.subject синхронизация ru_RU
dc.subject десинхронизация ru_RU
dc.subject медикаментозная седация ru_RU
dc.subject система "аппарат-пациент" ru_RU
dc.subject количественная оценка ru_RU
dc.subject artificial lung ventilation ru_RU
dc.subject synchronization ru_RU
dc.subject desynchronization ru_RU
dc.subject drug sedation ru_RU
dc.subject "apparatus-patient" system ru_RU
dc.subject quantitative assessment ru_RU
dc.subject Публикации кафедры "Программное обеспечение информационных технологий" ru_RU
dc.title Интегративный показатель тревог как объективный критерий эффективной синхронизации ИВЛ ru_RU
dc.title.alternative Integrative anxiety index as an objective criterion for eff ective synchronization of mechanical ventilation ru_RU
dc.type Article ru_RU


Файлы в этом документе

Данный элемент включен в следующие коллекции

Показать сокращенную информацию